IntroductionQuality ManagementReferencesPress RoomNews and eventsNews and events archivePrivacy StatementWebsite access conditions and legal restrictions
POWER WIRES AND CABLES LOW VOLTAGE POWER CABLESHALOGEN-FREE CABLES AND WIRESMEDIUM VOLTAGE POWER CABLESTELECOMMUNICATION CABLESLOW CURRENT CABLES AND WIRESSTRANDS, OVERHEAD LINESCatalog products in alphabetical order
Project ImplementationHome DeliveryVolume-based DiscountsSale of Reduced Value ProductsTechnical AdviceForeign CataloguesAreas of Service
Customized solutions
Stock Exchange NewsCurrency RatesThe Structure of Conductors Applicable StandardsCable Markings
Sales PersonnelRequest for customized quotePlacing an OrderPreliminary orderPresentationSales TerritoriesGTC
Contacts (Phone, Fax and E-mail)Map, How to Get ThereOn-line messaging
DownloadsWallpaperIndex, GlossaryDownloaderSitemap
Opening page      Contact      Sitemap    
ELECTRO-CORD : A KÁBEL PARTNER H-1117 Budapest, Hunyadi János út 16.   electrocord@electrocord.eu    Electro-Cord mapMap   

+36 1 371 0303    +36 30 341 0303    +36 1 371 0308            
   // www.electrocord.eu / Knowledge Base / Cable Markings






Cable Markings

(St) Al. foil screen with CU lead
_ J with yellow/green wire
_ EB sparkle-free
_ H extra flexible wire structure (eh)
_ K highly flexible wire structure (kh)
_ O without green/yellow wire (as indicator of batches)
_ R flexible structure conductor (h)
_ U solid conductor
_ Y Leoni core structure
_ JB with yellow/green wire, others coded
_ JZ with yellow/green wire, others numbered
_ OB colour coded wires
_ OZ with yellow/green wire, without numbered wires
_D standard flexibility
_E extra flexible
A approved national model
Aoutdoor cable
ABoutdoor cable with lightning protection
AJoutdoor cable with induction protection
AWG conductor structure in compliance with American standard
B 850 nm
Bd batch strand (star-four stranding)
BdiMF the cable is fully foil screened
C screening strand
Cu copper wire
D concentric stranded copper wire
E.Á. power transmission cable
e.á. high-voltage cable
E30 halogen free operating endurance 30 min
E90 halogen free operating endurance 90 min
ec solid trapezoidal conductor
EIB European installation BUS
ek solid round conductor
EPR ethylene-propylene rubber
F 1300 nm
F star four (railways)
FBfire alarm cable
FE 180 halogen free insulation, operating endurance 180 min
FEP teflon
FRfire resistant cable
FRNC the external cover is flame-resistant
G with yellow/green wire (as batch indicator)
Gmining cable
GJmining cable with external protection
GL glass fibre streaked
  
H 1550 nm
Jinstallation cable
JEinstallation cable (for industrial electronics)
Kx coaxial cable pair
Lflexible screened communications cable
Lg multi-lay concentric stranded (crown)
LG tubes, longitudinally stranded cores
Li litze
LOi with limited oxygen index
LSOH halogen free, minimum gas emission
MH installation (mounting) conductor
N complies with VDE standard
ö oil resistant
PiMF core pairs are screened with metal foil
PiMF screened core pair
PUR polyurethane
RDcontrol cable
RE solid round conductor
REdata link cable
RG Coax. Cable according to MiL specifications
RM stranded round conductor
RSdata link cable, IT switch cable)
S steel wire screen mechanical protection
S-switch cable for switchboards
S control cable (railways)
SE solid trapezoidal conductor
SL hose cable
SM stranded trapezoidal conductor
St star four (artefact line)
STI star four (telecommunication cable)
STIII star four (local cable)
tc stranded trapezoidal wire conductor
TF star four (for TF)
tk stranded round conductor
tkt stranded round conductor
TOi with temperature-dependent oxygen index
u flame resistant
v tin coated conductor ÖVE
ViMF core sets of 4 in metal foil
w heat resistant weather resistant
x without yellow/green wire (as batch indicator)
ZHLS halogen free, zero gas emission
   



























































HARMONIZED CONDUCTOR MARKINGS IN COMPLIANCE WITH VDE

In compliance with the harmonized document HD 361 S2 approved by SELENEC

   
Reference to standard
HMarking of harmonisation
AApproved national model
Rated voltage (U /U)
1100/100 V
3300/300 V
5300/500 V
7450/750 V
Insulation material
VPVC
V2Heat-resistant PVC (up to 90..5 °C)
RNatural rubber or styrolbutadiene rubber
GSynthetic rubber (up to 110°C-ig)
SSilicone rubber (up to 180°C)
Jacket material
VPVC
Rnatural rubber or styrolbutadiene rubber
Npolychloroprene rubber
N2rubber mixture
Jglass fibre mesh
Ttextile
T2textile with fire resistant cover
Customized design
Hflat divisible conductor
H2flat indivisible conductor
D3supporting element
D5without supporting element
Conductor Structure
Usolid
Rstranded
Kflexible for fixed installation
Fhighly flexible for mobile installation
Hextra flexible
Yleoni cable structure
Dflexible conductor for welding cable
Eextremely flexible conductor for welding cable
Number of cores
ndigit
Protective conductor
xmultiplier indicator without yellow/green wire
Gwith yellow/green wire instead of multiplier indicator
A(Nominal) cross sectional area (A) of the conductor in mm2

 
















































MARKINGS OF TELECOMMUNICATION CABLES AND CONDUCTORS
 complies with VDE

Base /basic type
A-outdoor cable
G-mining/mine cable
J-installation cable
Li-hose cable, extra flexible
Sswitch cable
Additional data
Blightning protected structure
Jinduction protection
Eelectronics
Insulation material
YPVC (polyvinyl-chloride)
2YPE (polyethylene)
02Yfibrous PE5Y
5YPTFE
6YFEP
Ppaper
Structural characteristics
Fvaseline filling
Laluminium jacket
LDcorrugated aluminium coating
(L)aluminium tape
(ST)metal foil shield
(K)copper tape shield
Ccopper wire mesh screen
(Z)steel wire mesh screen
Mplumb jacket
Mzspecial plumb jacket
barmour (shielding)
cjute (gunny) cover + massa
Emassa layer + tape
Jacket material
YPVC (polyvinyl-chloride)
2YPE (polyethylene)
02Yfibrous PE5Y
5YPTFE
6YFEP
Ppaper
Number of elements
 number of stranded elements
Stranded element
1wire
2pair
Conductor Cross-sectional Area
mm(in certain cases mm2)
Stranded element
Fstar four (railways)
Ststar four (artefact line)
StIstar four (telecommunication cable)
StIIIstar four (local)
TFstar four for TF
PiMFPiMF screened wire pair
Method of stranding
Lgmulti-lay strand
Bgbatched stranding
  
HUNGARIAN MARKINGS ON POWER TRANSMISSION CABLES 


Standard referencing
SzIn compliance with MSz Standard
Conductor material
Rcopper
Aaluminium
Insulation material
MPVC (polyvinyl-chloride)
QPE (polyethylene)
Xcross-linked PE
Materials of shield / belt layer
eextruded design
tcoiled/in-coil design
Separation mark between cables and shield / cover
K 
Metal Coating Material
Aaluminium
spress-formed (extruded) design
Shield/Screen Material
Rcopper
Aaluminium
Shield/Screen design
kround wire
lflat wire
tcoiled tape
hlongitudinal tape
Separating/Separation layer
E 
Armour / shield material
Vsteel design
kround wire
lflat / flattened wire
Outer Shield/Cover Material
MPVC (polyvinyl-chloride)
QPE (polyethylene)
Signalling/Signal cable Signalling equipment operation cable marking
J 

Conductor design
eksolid round conductor
ecsolid trapezoidal conductor
tkstranded round conductor
tcstranded trapezoidal conductor
tktstranded round compacted
sfinishing/smoothing layer on conductor
  
HUNGARIAN MARKINGS ON TELECOMMUNICATION CABLES
 
Cable Type Markings
Ccoaxial wire:
Bactuator cable
Hlocal telephone and mining cable
Ttelecommunication cable
Lself-sustaining overhead cable
Sswitch cable
Fwall cable
Markings of conductor material
Rcopper
Rotin coated copper conductor
Aaluminium
Markings of insulation materials
Ppaper
MPVC (polyvinyl-chloride)
QPE (polyethylene)
Qhcellular polyethylene
QhQcell-skin polyethylene
Separation mark between cables and jacket structure
Markings of jacket structure
AhLongitudinal aluminium jacket
AtCoiled aluminium
AkAluminium (wire) shield
RhLongitudinal copper shield
OPress-formed plumb jacket
MExtruded PVC jacket
QExtruded PE jacket
VSteel armoured
VkRound wire, armoured
VxHalf-closed profile wire
BSaturated jute (gunny) cover
Markings of space filling
zvaseline space filling material
Nominal number of base elements
 digit
 
POWER TRANSMISSION AND MEDIUM VOLTAGE CABLE MARKINGS IN COMPLIANCE WITH VDE 

Reference to a standard
N 
(N) 
Conductor material
 copper is not marked
Aaluminium
Insulation material
 saturated paper is not marked
YPVC (polyvinyl-chloride)
2YPE (polyethylene)
2XVPE (cross-linked PE)
HXhalogen-free insulation
Screening or concentric 0 conductor
Cconcentric copper conductor
CWconcentric corrugated copper conductor
Scopper wire screening in common jacket
SEcopper mesh screen per core
Hmetal-covered paper screening
Cores individually wrapped (Höchstädter foil)
Jacket
YPVC (polyvinyl-chloride)
2YPE (polyethylene)
Eprotective tape with embedded layer
(F)longitudinal waterproof layer
(FL)longitudinal and concentric waterproof screen/shield
Armouring / armour (shielding)
Bsteel tape
Fflat steel wires
RRound steel wire
Gwire strand tying reverse spiral steel tape
Outer cover / coat
ASaturated tarry fibres (jute)
YPVC (polyvinyl-chloride)
2YPE (polyethylene)
Gwire-strand tying tape
Other
Jwith yellow/green wire
Owithout yellow/green wire
Number of wires
Nominal Cross-sectional Area of Conductor
mm² 
Conductor core structure
REsolid round
RMstranded round
SEsolid trapezoidal
SMstranded trapezoidal
Nominal Cross-sectional Area of screening wire or 0 conductor
mm² 
Nominal voltage
 0,6/1 kV
 3,6//6 kV
 6/10 kV
 12/20 kV
 18/30 kV
 20/35 kV
 40/69 kV
 64/110 kV
 76/132 kV
     


File formats


A dokumentum megtekinthető az alábbi formátumokban is:
- Microsoft Word Document formátum: http://electrocord.eu/d256-Cable-Markings.doc

 
 

Jump to top | Electrocord.eu opening page | Contact | Sitemap
Products | Services | Solutions | Knowedge Base | Sales | Customer Service | Extras

Privacy Statement | Electrocord.eu website access conditions and legal restrictions

Copyright © 2008-2011 WWW.MAXELINE.HU Kft.