Cable Markings| (St) | Al. foil screen with CU lead | | _ J | with yellow/green wire | | _ EB | sparkle-free | | _ H | extra flexible wire structure (eh) | | _ K | highly flexible wire structure (kh) | | _ O | without green/yellow wire (as indicator of batches) | | _ R | flexible structure conductor (h) | | _ U | solid conductor | | _ Y | Leoni core structure | | _ JB | with yellow/green wire, others coded | | _ JZ | with yellow/green wire, others numbered | | _ OB | colour coded wires | | _ OZ | with yellow/green wire, without numbered wires | | _D | standard flexibility | | _E | extra flexible | | A | approved national model | | A | outdoor cable | | AB | outdoor cable with lightning protection | | AJ | outdoor cable with induction protection | | AWG | conductor structure in compliance with American standard | | B | 850 nm | | Bd | batch strand (star-four stranding) | | BdiMF | the cable is fully foil screened | | C | screening strand | | Cu | copper wire | | D | concentric stranded copper wire | | E.Á. | power transmission cable | | e.á. | high-voltage cable | | E30 | halogen free operating endurance 30 min | | E90 | halogen free operating endurance 90 min | | ec | solid trapezoidal conductor | | EIB | European installation BUS | | ek | solid round conductor | | EPR | ethylene-propylene rubber | | F | 1300 nm | | F | star four (railways) | | FB | fire alarm cable | | FE 180 | halogen free insulation, operating endurance 180 min | | FEP | teflon | | FR | fire resistant cable | | FRNC | the external cover is flame-resistant | | G | with yellow/green wire (as batch indicator) | | G | mining cable | | GJ | mining cable with external protection | | GL | glass fibre streaked |
| H | 1550 nm | | J | installation cable | | JE | installation cable (for industrial electronics) | | Kx | coaxial cable pair | | L | flexible screened communications cable | | Lg | multi-lay concentric stranded (crown) | | LG | tubes, longitudinally stranded cores | | Li | litze | | LOi | with limited oxygen index | | LSOH | halogen free, minimum gas emission | | MH | installation (mounting) conductor | | N | complies with VDE standard | | ö | oil resistant | | PiMF | core pairs are screened with metal foil | | PiMF | screened core pair | | PUR | polyurethane | | RD | control cable | | RE | solid round conductor | | RE | data link cable | | RG | Coax. Cable according to MiL specifications | | RM | stranded round conductor | | RS | data link cable, IT switch cable) | | S | steel wire screen mechanical protection | | S- | switch cable for switchboards | | S | control cable (railways) | | SE | solid trapezoidal conductor | | SL | hose cable | | SM | stranded trapezoidal conductor | | St | star four (artefact line) | | STI | star four (telecommunication cable) | | STIII | star four (local cable) | | tc | stranded trapezoidal wire conductor | | TF | star four (for TF) | | tk | stranded round conductor | | tkt | stranded round conductor | | TOi | with temperature-dependent oxygen index | | u | flame resistant | | v | tin coated conductor ÖVE | | ViMF | core sets of 4 in metal foil | | w | heat resistant weather resistant | | x | without yellow/green wire (as batch indicator) | | ZHLS | halogen free, zero gas emission |
HARMONIZED CONDUCTOR MARKINGS IN COMPLIANCE WITH VDE In compliance with the harmonized document HD 361 S2 approved by SELENEC
| Reference to standard | | H | Marking of harmonisation | | A | Approved national model | | Rated voltage (U /U) | | 1 | 100/100 V | | 3 | 300/300 V | | 5 | 300/500 V | | 7 | 450/750 V | | Insulation material | | V | PVC | | V2 | Heat-resistant PVC (up to 90..5 °C) | | R | Natural rubber or styrolbutadiene rubber | | G | Synthetic rubber (up to 110°C-ig) | | S | Silicone rubber (up to 180°C) | | Jacket material | | V | PVC | | R | natural rubber or styrolbutadiene rubber | | N | polychloroprene rubber | | N2 | rubber mixture | | J | glass fibre mesh | | T | textile | | T2 | textile with fire resistant cover | | Customized design | | H | flat divisible conductor | | H2 | flat indivisible conductor | | D3 | supporting element | | D5 | without supporting element | | Conductor Structure | | U | solid | | R | stranded | | K | flexible for fixed installation | | F | highly flexible for mobile installation | | H | extra flexible | | Y | leoni cable structure | | D | flexible conductor for welding cable | | E | extremely flexible conductor for welding cable | | Number of cores | | n | digit | | Protective conductor | | x | multiplier indicator without yellow/green wire | | G | with yellow/green wire instead of multiplier indicator | | A | (Nominal) cross sectional area (A) of the conductor in mm2 |
MARKINGS OF TELECOMMUNICATION CABLES AND CONDUCTORS complies with VDE
| Base /basic type | | A- | outdoor cable | | G- | mining/mine cable | | J- | installation cable | | Li- | hose cable, extra flexible | | S | switch cable | | Additional data | | B | lightning protected structure | | J | induction protection | | E | electronics | | Insulation material | | Y | PVC (polyvinyl-chloride) | | 2Y | PE (polyethylene) | | 02Y | fibrous PE5Y | | 5Y | PTFE | | 6Y | FEP | | P | paper | | Structural characteristics | | F | vaseline filling | | L | aluminium jacket | | LD | corrugated aluminium coating | | (L) | aluminium tape | | (ST) | metal foil shield | | (K) | copper tape shield | | C | copper wire mesh screen | | (Z) | steel wire mesh screen | | M | plumb jacket | | Mz | special plumb jacket | | b | armour (shielding) | | c | jute (gunny) cover + massa | | E | massa layer + tape | | Jacket material | | Y | PVC (polyvinyl-chloride) | | 2Y | PE (polyethylene) | | 02Y | fibrous PE5Y | | 5Y | PTFE | | 6Y | FEP | | P | paper | | Number of elements | | | number of stranded elements | | Stranded element | | 1 | wire | | 2 | pair | | Conductor Cross-sectional Area | | mm | (in certain cases mm2) | | Stranded element | | F | star four (railways) | | St | star four (artefact line) | | StI | star four (telecommunication cable) | | StIII | star four (local) | | TF | star four for TF | | PiMF | PiMF screened wire pair | | Method of stranding | | Lg | multi-lay strand | | Bg | batched stranding |
HUNGARIAN MARKINGS ON POWER TRANSMISSION CABLES
| Standard referencing | | Sz | In compliance with MSz Standard | | Conductor material | | R | copper | | A | aluminium | | Insulation material | | M | PVC (polyvinyl-chloride) | | Q | PE (polyethylene) | | X | cross-linked PE | | Materials of shield / belt layer | | e | extruded design | | t | coiled/in-coil design | | Separation mark between cables and shield / cover | | K | | | Metal Coating Material | | A | aluminium | | s | press-formed (extruded) design | | Shield/Screen Material | | R | copper | | A | aluminium | | Shield/Screen design | | k | round wire | | l | flat wire | | t | coiled tape | | h | longitudinal tape | | Separating/Separation layer | | E | | | Armour / shield material | | V | steel design | | k | round wire | | l | flat / flattened wire | | Outer Shield/Cover Material | | M | PVC (polyvinyl-chloride) | | Q | PE (polyethylene) | | Signalling/Signal cable Signalling equipment operation cable marking | | J | | Conductor design | | ek | solid round conductor | | ec | solid trapezoidal conductor | | tk | stranded round conductor | | tc | stranded trapezoidal conductor | | tkt | stranded round compacted | | s | finishing/smoothing layer on conductor |
HUNGARIAN MARKINGS ON TELECOMMUNICATION CABLES | Cable Type Markings | | C | coaxial wire: | | B | actuator cable | | H | local telephone and mining cable | | T | telecommunication cable | | L | self-sustaining overhead cable | | S | switch cable | | F | wall cable | | Markings of conductor material | | R | copper | | Ro | tin coated copper conductor | | A | aluminium | | Markings of insulation materials | | P | paper | | M | PVC (polyvinyl-chloride) | | Q | PE (polyethylene) | | Qh | cellular polyethylene | | QhQ | cell-skin polyethylene | | Separation mark between cables and jacket structure | | Markings of jacket structure | | Ah | Longitudinal aluminium jacket | | At | Coiled aluminium | | Ak | Aluminium (wire) shield | | Rh | Longitudinal copper shield | | O | Press-formed plumb jacket | | M | Extruded PVC jacket | | Q | Extruded PE jacket | | V | Steel armoured | | Vk | Round wire, armoured | | Vx | Half-closed profile wire | | B | Saturated jute (gunny) cover | | Markings of space filling | | z | vaseline space filling material | | Nominal number of base elements | | | digit |
POWER TRANSMISSION AND MEDIUM VOLTAGE CABLE MARKINGS IN COMPLIANCE WITH VDE | Reference to a standard | | N | | | (N) | | | Conductor material | | | copper is not marked | | A | aluminium | | Insulation material | | | saturated paper is not marked | | Y | PVC (polyvinyl-chloride) | | 2Y | PE (polyethylene) | | 2X | VPE (cross-linked PE) | | HX | halogen-free insulation | | Screening or concentric 0 conductor | | C | concentric copper conductor | | CW | concentric corrugated copper conductor | | S | copper wire screening in common jacket | | SE | copper mesh screen per core | | H | metal-covered paper screening | | Cores individually wrapped (Höchstädter foil) | | Jacket | | Y | PVC (polyvinyl-chloride) | | 2Y | PE (polyethylene) | | E | protective tape with embedded layer | | (F) | longitudinal waterproof layer | | (FL) | longitudinal and concentric waterproof screen/shield | | Armouring / armour (shielding) | | B | steel tape | | F | flat steel wires | | R | Round steel wire | | G | wire strand tying reverse spiral steel tape | | Outer cover / coat | | A | Saturated tarry fibres (jute) | | Y | PVC (polyvinyl-chloride) | | 2Y | PE (polyethylene) | | G | wire-strand tying tape | | Other | | J | with yellow/green wire | | O | without yellow/green wire | | Number of wires | | Nominal Cross-sectional Area of Conductor | | mm² | | | Conductor core structure | | RE | solid round | | RM | stranded round | | SE | solid trapezoidal | | SM | stranded trapezoidal | | Nominal Cross-sectional Area of screening wire or 0 conductor | | mm² | | | Nominal voltage | | | 0,6/1 kV | | | 3,6//6 kV | | | 6/10 kV | | | 12/20 kV | | | 18/30 kV | | | 20/35 kV | | | 40/69 kV | | | 64/110 kV | | | 76/132 kV |